790 research outputs found

    An instrumental prototype for in-vivo measurements of biological tissue oxygenation

    Get PDF
    Near infrared (NIR) spectroscopy is gaining importance as a technique for the noninvasive in-vivo determination of the oxygen content of biological tissues. In tissue, oxygen is transported by haemoglobin, which is the dominating optical absorber in the NIR wavelength range. Since the NIR absorption spectra of oxi- and deoxihaemoglobin are different, tissue oxygen saturation can be determined from NIR absorption at (at least) two wavelengths, which can be measured by optical backscattering. To this purpose INFM UdR Pavia (1) has developed a prototype for a dedicated handheld dual wavelength oxygen monitor, for measurements with minimal patient discomfort. The instrument, which works with time-multiplexed LED sources, is battery powrered, compact and light in weight. By employing a mixed-signal single-chip microcontroller and EEPROM storage of the measured data, it does not require the connection to external data acquisition systems. Moreover, by choosing electronic components which are currently available on the consumer electronics market, the instrument is suitable for mass production. Even though an accurate absolute calibration of the instrument still remains an open problem, preliminary measurements on forearm ischemia show a detectivity and a time response which are adequate for semiquantitative large muscle oxygenation studies

    Apparatus for time‐resolved measurements of acoustic birefringence in particle dispersions

    Get PDF
    An apparatus for time‐resolved measurements of the birefringence induced in a particle suspension by an acoustic wave pulse is described. Efficient acoustic coupling is obtained by operating near the transducer resonant frequency and by matching the acoustic impedances of the cell constituents. An almost‐overdamped acoustic configuration can alternatively be employed whenever a faster response is needed. Careful design of the optical setup and of the detection unit minimize diffraction and stress‐birefringence parasitic effects and yields a good responsivity at fairly low acoustic intensities. A test of the apparatus on a colloidal suspension of PTFE rodlike particles is presented and discussed

    Near-infrared spectroscopy study of tourniquet-induced forearm ischaemia in patients with coronary artery disease

    Get PDF
    Near-Infrared Spectroscopy (NIR) can be employed to monitor local changes in haemodynamics and oxygenation of human tissues. A preliminary study has been performed in order to evaluate the NIRS transmittance response to induced forearm ischaemia in patients with coronary artery disease (CAD). The population consists in 40 patients with cardiovascular risk factors and angiographically documented CAD, compared to a group of 13 normal subjects. By inflating and subsequently deflating a cuff placed around the patient arm, an ischaemia has been induced and released, and the patients have been observed until recovery of the basal conditions. A custom LAIRS spectrometer (IRIS) has been used to collect the backscattered light intensities from the patient forearm throughout the ischaemic and the recovery phase. The time dependence of the near-infrared transmittance on the control group is consistent with the available literature. On the contrary, the magnitude and dynamics of the NIRS signal on the CAD patients show deviations from the documented normal behavior, which can be tentatively attributed to abnormal vessel stiffness. These preliminary results, while validating the performance of the IRIS spectrometer, are strongly conducive towards the applicability of the NIRS technique to ischaemia analysis and to endothelial dysfunction characterization in CAD patients with cardiovascular risk factors.Publisher PD

    The diabetic retinopathy screening workflow : potential for smartphone imaging

    Get PDF
    Complications of diabetes mellitus, namely diabetic retinopathy and diabetic maculopathy, are the leading cause of blindness in working aged people. Sufferers can avoid blindness if identified early via retinal imaging. Systematic screening of the diabetic population has been shown to greatly reduce prevalence and incidence of blindness within the population. Many national screening programmes have digital fundus photography as their basis. In the past five years several techniques and adapters have been developed that allow digital fundus photography to be performed using smartphones. We review recent progress in smartphone - based fundus imaging and discuss its potential for integration into national systematic DR screening programmes. Some systems have produced promising initial results with respect to their agreement with reference standards. However further multi-site trialling of such systems’ use withi n implementable screening workflows is required if an evidence base strong enough to affect policy change is to be established. If this were to occur national diabetic retinopathy screening would, for the first time, become possible in low-and middle-income settings where cost and availability of trained eye-care personnel are currently key barriers to implementation. As diabetes prevalence and incidence is increasing sharply in these settings, the impact on global blindness could be profound

    Towards a workflow driven design for mHealth devices within temporary eye clinics in low-income settings

    Get PDF
    Only a small minority of mobile healthcare technologies that have been successful in pilot studies have subsequently been integrated into healthcare systems. Understanding the reasons behind this discrepancy is crucial if such technologies are to be adopted. We believe that the mismatch is due to a breakdown in the relation between technical soundness of the original mobile health (mHealth) device design, and integration into healthcare provision workflows. Quantitative workflow modelling provides an opportunity to test this hypothesis. In this paper we present our current progress in developing a clinical workflow model for mobile eye assessment in low-income settings. We test the model for determining the appropriateness of design parameters of a mHealth device within this workflow, by assessing their impact on the entire clinical workflow performance

    Process parameters effect on mechanical properties and fatigue behaviour of friction stir weld AA6060 joints

    Get PDF
    Friction stir welding (FSW) is the most remarkable welding technology that has been invented and developed in the last decade. It is a solid-state welding process in which a rotating tool is driven into the material and translated along the interface of two or more plates. This technology has been successfully used to join materials that are considered difficult to be welded by fusion welding methods. FSW has potentially significant applications in many industrial fields such as aerospace, automotive, and naval industry. Anyway, FSW technology requires a meticulous understanding of the process and consequent mechanical properties of the welds in order to be used in the production of high performance components. The present work deals with an experimental campaign aimed at the evaluation of the mechanical properties of AA6060 T6 friction stir welded joints. The butt joints obtained using two different tool geometries (standard and threaded) were performed by varying the welding parameters, namely, tool rotating speed and feed rate. The standard tool was a very simple device fabricated using AISI 1040 steel, with a flat shoulder and a cylindrical pin. The threaded tool was a more complex device based on two main components: a tool holder, with a flat shoulder, and a threaded probe obtained using a commercial thread forming tap. The quality of the joints was evaluated in terms of both tensile strength (UTS) and fatigue behavior. The study of axial pulsing fatigue properties required the fabrication of a specific testing device able to avoid parasite bending moments. In order to estimate the more efficient and effective tool type, the welding forces (axial and longitudinal) were also measured

    Probing for local activity-related modulation of the infrared backscattering of the brain cortex

    Get PDF
    The possibility to measure the metabolic activity of the brain cortex, with submillimeter spatial and subsecond temporal resolution, would open up enticing scenarios in addressing basic issues on the relation between different structural components of brain signal processing, and in providing an operational pathway to interaction with (dis)functional signal patterns. In the present article, we report the description of a simple system that allows the detection of the minute changes that occur in the optical backscattering of the cortex as a metabolic response to external stimuli. The simplicity of the system is compatible with scalability to an implantable probe. We validate the system on an animal model, and we propose an algorithm to extract meaningful data from the measured signal. We thus show the detection of individual haemodynamic cortical responses to individual stimulation events, and we provide operational considerations on the signal structure

    Next-generation ophthalmic diagnostics

    Get PDF
    We are developing a fully automated mobile application (app) to test for contrast sensitivity by measuring the ability of the patient to follow a moving dot on a digital screen. The test results are evaluated automatically using algorithms that measure the gaze direction of the user. Here we present preliminary results of the app development

    Photometric compliance of tablet screens and retro-illuminated acuity charts as visual acuity measurement devices

    Get PDF
    Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≄ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≄ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≄ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≄ 120 cd/m2) and Weber contrast (≄ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≄ 80%). Two charts were operating beyond manufacturer’s recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out-performed ETDRS charts in terms of photometric compliance with high contrast acuity standards

    Effects of Lactobacillus acidophilus D2/CSL (CECT 4529) supplementation on healthy cat performance

    Get PDF
    Background The present study aimed to evaluate the effects of the probiotic strain Lactobacillusacidophilus D2/CSL (CECT 4529) on nutritional condition and faecal quality in cats. Methods Ten healthy adult cats from the same cattery were included (aged >9 months; male:female sex ratio=3:7). The animals were randomly assigned to a control group (CTR; n=5; male:female=1:4; room 1: 16 m 2) and to a treated group (LACTO; n=5; male:female=2:3; room 2: 16 m 2) receiving the same commercial dry diet. The LACTO group diet was supplemented with the probiotic (5 x 10 9 cfu/kg feed at least). A five-week experimental period was applied, and nutritional status was monitored by bodyweight (BW) and body condition score (BCS). Faecal quality was evaluated using faecal score (FS) and faecal moisture (FM) parameters. Plate counts of some faecal bacteria species were carried out. The data obtained were analysed using MIXED, GLM and NPAR1WAY procedures (SAS V.9.4; P 640.05). Results The two groups did not show differences in BW and BCS data. A clear effect of the probiotic supplementation on FM was recorded (LACTO 44 per cent v CTR group 46 per cent; P=0.04). FS in the LACTO group (3.35) was close to ideal values (2-3) in comparison with the CTR group (3.75). Positive effects of Lacidophilus D2/CSL have been recorded in terms of increase in faecal lactobacilli counts and reduction in faecal coli counts. Conclusions This study's preliminary results describe how inclusion of Lacidophilus D2/CSL (CECT 4529) probiotic strain in cats' diets could effectively improve faecal quality parameters and consequently gut health in adult healthy cats
    • 

    corecore